Code: ENIGMA III User Manual
Edition: 1 Revision: 4
Date: 19/12/2008
Page: 63/97
Unit: dB
6.15.1 noisePowerH
Noise power on horizontal channel as measured by the noisesample command.
Type: float
Default: 0.0
6.15.2 noisePowerV
Noise power on vertical channel as measured by the noisesample command.
Type: float
Default: 0.0
6.16 dbz0
Horizontal/vertical calibration reflectivity for 4 pulse widths. dBZ
0
is a calibration reflectivity, that is the
minimum detectable dBZ at the reference range 1 km;
Calibration reflectivity table is in the 'dbz0' parameter.
Format of argument: <dbz0_pulse0_hor> <dbz0_pulse0_ver> ... <dbz0_pulse3_hor> <dbz0_pulse3_ver>
Default value: all array members are set to 0.0
6.17 RangeNorm
Range normalization algorithm switch.
20 log(r) is the range normalization, expressed in dB
Type: boolean
Default: true